JRST Technology
Free planning tool

Plan your wafer, ingot and crucible needs per GW.

Enter a cell or module capacity and a few process assumptions to see how many wafers, how much silicon ingot and how many quartz crucibles a year that implies. Every input is editable.

Annual requirement (illustrative)130.2 M wafers
  • 7.92 W rated power per cell
  • 13.8 g silicon per wafer incl. kerf
  • 1,802 t silicon in bricks sliced
  • 2,574 t ingot grown
  • – quartz crucibles (enter charge per crucible)

Every default is an illustrative, editable assumption, not JRST data. Results are first-pass planning estimates and must be validated against your equipment, process and supplier specifications.

Discuss wafer supply with JRST
How the calculation works

Four steps from gigawatts to grams of silicon.

01

Power per cell

Wafer area × 1,000 W/m² standard irradiance × cell efficiency gives each cell's rated power. Capacity divided by that gives the good cells needed; line yield grosses it up to wafers.

02

Silicon per wafer

Area × (wafer thickness + kerf) × 2.33 g/cm³. Kerf is the silicon the diamond wire turns into dust on every cut, so it counts as consumed silicon.

03

Ingot and crucibles

Brick silicon ÷ ingot-to-brick yield gives ingot grown. Enter your own polysilicon charge per crucible to estimate crucible count; the tool does not assume one.

Assumptions and limits

A sizing aid, not a plant design.

Defaults (M10 about 330 cm², G12 about 441 cm², 24% efficiency, 130 µm wafer, 50 µm kerf, 97% line yield, 70% ingot-to-brick yield) are illustrative round numbers chosen for the worked example, not JRST production data. Real values vary by technology, wire, puller and recipe. The tool ignores melt residue, recycling of crops and squaring offcuts, breakage in handling and module-level losses. Read the background in our guides on wafer sizes, the Czochralski method and quartz crucibles, or browse wafers, crucibles and spares in our product catalogue.

FAQ

Wafer requirement questions.

How many solar wafers are needed for 1 GW?

It depends mainly on wafer size and cell efficiency. With the illustrative defaults on this page (M10 wafer of about 330 cm² and 24% cell efficiency) each cell is rated at roughly 7.9 W, so about 126 million good cells are needed per GW, and somewhat more wafers once line yield is allowed for. Larger wafers or higher efficiency reduce the count.

How is the silicon requirement calculated?

Each wafer's silicon is its area multiplied by its thickness plus the kerf lost to the wire saw, times silicon's density of about 2.33 g/cm³. Dividing the sliced-brick silicon by the ingot-to-brick yield gives the ingot that must be grown, before melt residue and recycling are considered.

Can this calculator size a plant or its cost?

No. It converts a capacity target into first-pass material quantities only. Equipment counts, pull cycles, power, consumables and economics depend on the specific process and suppliers and need a detailed engineering study.

Built by practitioners

Prepared by Mohammed Saif Zaveri, Co-Founder & Director of JRST Technology, and the JRST Industrial Advisory Team. For ingot-wafer plant setup see our ingot-wafer plant setup service; for merchant wafer or crucible enquiries use the Buyer Portal at app.jrsttechnology.com/portal.

Begin with the requirement, not a catalogue.

Turn a GW target into a validated wafer plan.

Book a consultation